Residual Current Devices Professional

GREEN ELECTRIC®

The highest level of precision
The measuring system of the ground fault circuit interrupter (fault-current circuit breaker) equipped with a summation current transformer records alternating current and pulsating direct residual current and is insensitive to surge currents up to 250A. In accordance with DIN VDE 0664 Part 1, shut down in the event of a fault occurs within 0.2 seconds.

Easy installation
The patented quick-action fastening of the Kopp MCB is also used in the fault-current circuit breakers (ground fault circuit interrupters). This allows it to be locked to the DIN rail easily and if required also released from the assembly.

Integrated error signal display
As with the Kopp MCB circuit breaker, the cause of tripping in the case of fault-current circuit breakers (ground fault circuit interrupters) can also be used determined from the position of the knob. Is the knob is downwards, the ground fault circuit interrupter (fault-current circuit breaker) was manually turned off. However, if the knob is in the middle, the device was tripped by a residual current in the system. In order turn the ground fault circuit interrupter (fault-current circuit breaker) back on again, the knob must first be pushed down before the it can be pushed up to the “On Position” again.

Well thought-out connection technology
Factory-made open terminals for ground fault circuit interrupters (residual current circuit breakers) and the option of cross-wiring the devices with the bus bar help you to save on installation time and thus on cost too.

DescriptionArticle NrEANPU
Residual Current Device (RCD), 2-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75162301940082241612821
Residual Current Device (RCD), 2-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75162601240082241612991
Residual Current Device (RCD), 2-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75162801440082241613051
Residual Current Device (RCD), 2-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75252801240082241613431
Residual Current Device (RCD), 2-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75252301740082241613291
Residual Current Device (RCD), 2-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75402801940082241613741
Residual Current Device (RCD), 2-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75402101240082243773001
Residual Current Device (RCD), 2-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75402301440082241613501
Residual Current Device (RCD), 2-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75632801040082241614111
Residual Current Device (RCD), 2-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75632301540082241613811
Residual Current Device (RCD), 4-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75254801640082241572161
Residual Current Device (RCD), 4-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75254101940082241572231
Residual Current Device (RCD), 4-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75254301140082241572301
Residual Current Device (RCD), 4-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75254501340082241572471
Residual Current Device (RCD), 4-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75404801340082241572541
Residual Current Device (RCD), 4-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75404101640082241573221
Residual Current Device (RCD), 4-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75404301840082241573391
Residual Current Device (RCD), 4-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75404501040082241573461
Residual Current Device (RCD), 4-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75634801440082241573531
Residual Current Device (RCD), 4-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75634101740082241574381
Residual Current Device (RCD), 4-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75634301940082241574451
Residual Current Device (RCD), 4-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75634501140082241574691
Residual Current Device (RCD), 4-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75014179240082244259261
Residual Current Device (RCD), 4-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75014579640082244259401
Residual Current Device (RCD), 4-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75024379740082244259711
Residual Current Device (RCD), 4-pole, A-type, DINVDE 0664, EN 61008, sensitive for alternating and pulsating DC residual currents75024579940082244259881
Residual Current Device (RCD), 2-pole, to ÖVE SN 50, EN 61008, AC-type, detects only alternating leakage currents79632801840082243721381